DocumentCode
1730211
Title
Evaluation of NRC-FCs1: Mapping the C-field using the Larmor frequency
Author
Marmet, Louis ; Gertsvolf, Marina
Author_Institution
Inst. for Nat. Meas. Stand., Nat. Res. Council Canada, Ottawa, ON, Canada
fYear
2010
Firstpage
312
Lastpage
317
Abstract
An uncertainty evaluation of NRC´s cesium fountain clock FCs1 is currently being performed. One task of this evaluation consists in quantifying the contribution to the frequency uncertainty, the second-order Zeeman shift. We report the results obtained from measurements of the C-field above the Ramsey cavity using the Larmor frequency as a probe. This technique is possible because a transverse C-field is used in NRC-FCs1 and alignment electrodes are available to produce an orthogonal excitation field. The non-uniformity of the C-field near the Ramsey cavity and the uncertainties in the measurements produce the largest contribution to the type-B uncertainty.
Keywords
caesium; cavity resonators; C-field; Ramsey cavity; frequency uncertainty; larmor frequency; orthogonal excitation field; second-order Zeeman shift; Atomic clocks; Atomic measurements; Cavity resonators; Clouds; Frequency measurement; Magnetic field measurement; Magnetic fields;
fLanguage
English
Publisher
ieee
Conference_Titel
Frequency Control Symposium (FCS), 2010 IEEE International
Conference_Location
Newport Beach, CA
ISSN
1075-6787
Print_ISBN
978-1-4244-6399-2
Type
conf
DOI
10.1109/FREQ.2010.5556322
Filename
5556322
Link To Document