• DocumentCode
    1730211
  • Title

    Evaluation of NRC-FCs1: Mapping the C-field using the Larmor frequency

  • Author

    Marmet, Louis ; Gertsvolf, Marina

  • Author_Institution
    Inst. for Nat. Meas. Stand., Nat. Res. Council Canada, Ottawa, ON, Canada
  • fYear
    2010
  • Firstpage
    312
  • Lastpage
    317
  • Abstract
    An uncertainty evaluation of NRC´s cesium fountain clock FCs1 is currently being performed. One task of this evaluation consists in quantifying the contribution to the frequency uncertainty, the second-order Zeeman shift. We report the results obtained from measurements of the C-field above the Ramsey cavity using the Larmor frequency as a probe. This technique is possible because a transverse C-field is used in NRC-FCs1 and alignment electrodes are available to produce an orthogonal excitation field. The non-uniformity of the C-field near the Ramsey cavity and the uncertainties in the measurements produce the largest contribution to the type-B uncertainty.
  • Keywords
    caesium; cavity resonators; C-field; Ramsey cavity; frequency uncertainty; larmor frequency; orthogonal excitation field; second-order Zeeman shift; Atomic clocks; Atomic measurements; Cavity resonators; Clouds; Frequency measurement; Magnetic field measurement; Magnetic fields;