DocumentCode :
1730211
Title :
Evaluation of NRC-FCs1: Mapping the C-field using the Larmor frequency
Author :
Marmet, Louis ; Gertsvolf, Marina
Author_Institution :
Inst. for Nat. Meas. Stand., Nat. Res. Council Canada, Ottawa, ON, Canada
fYear :
2010
Firstpage :
312
Lastpage :
317
Abstract :
An uncertainty evaluation of NRC´s cesium fountain clock FCs1 is currently being performed. One task of this evaluation consists in quantifying the contribution to the frequency uncertainty, the second-order Zeeman shift. We report the results obtained from measurements of the C-field above the Ramsey cavity using the Larmor frequency as a probe. This technique is possible because a transverse C-field is used in NRC-FCs1 and alignment electrodes are available to produce an orthogonal excitation field. The non-uniformity of the C-field near the Ramsey cavity and the uncertainties in the measurements produce the largest contribution to the type-B uncertainty.
Keywords :
caesium; cavity resonators; C-field; Ramsey cavity; frequency uncertainty; larmor frequency; orthogonal excitation field; second-order Zeeman shift; Atomic clocks; Atomic measurements; Cavity resonators; Clouds; Frequency measurement; Magnetic field measurement; Magnetic fields;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Frequency Control Symposium (FCS), 2010 IEEE International
Conference_Location :
Newport Beach, CA
ISSN :
1075-6787
Print_ISBN :
978-1-4244-6399-2
Type :
conf
DOI :
10.1109/FREQ.2010.5556322
Filename :
5556322
Link To Document :