• DocumentCode
    1730716
  • Title

    Detection and characterization of defects in microelectronic packages and boards by means of high-resolution x-ray computed tomography (CT)

  • Author

    Pacheco, Mario ; Goyal, Deepak

  • Author_Institution
    Intel Corp., Chandler, AZ, USA
  • fYear
    2011
  • Firstpage
    1263
  • Lastpage
    1268
  • Abstract
    In this paper a review of the development of x-ray computed tomography (CT) for non-destructive failure analysis in microelectronics packages and boards is presented. The general operation principle, key design considerations and technical challenges faced by x-ray CT technology are discussed. A comparison between 2D and 3D x-ray imaging capabilities is presented, and critical failure analysis case studies for first and second level interconnect that are hard or not possible to isolate by alternative methods are also discussed, as well as its unique progressive testing capability.
  • Keywords
    X-ray imaging; computerised tomography; electronics packaging; failure analysis; X-ray imaging; critical failure analysis; high-resolution X-ray computed tomography; microelectronic packages; nondestructive failure analysis; Computed tomography; Image reconstruction; Image resolution; Microelectronics; Soldering; Three dimensional displays; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronic Components and Technology Conference (ECTC), 2011 IEEE 61st
  • Conference_Location
    Lake Buena Vista, FL
  • ISSN
    0569-5503
  • Print_ISBN
    978-1-61284-497-8
  • Electronic_ISBN
    0569-5503
  • Type

    conf

  • DOI
    10.1109/ECTC.2011.5898673
  • Filename
    5898673