DocumentCode
1730716
Title
Detection and characterization of defects in microelectronic packages and boards by means of high-resolution x-ray computed tomography (CT)
Author
Pacheco, Mario ; Goyal, Deepak
Author_Institution
Intel Corp., Chandler, AZ, USA
fYear
2011
Firstpage
1263
Lastpage
1268
Abstract
In this paper a review of the development of x-ray computed tomography (CT) for non-destructive failure analysis in microelectronics packages and boards is presented. The general operation principle, key design considerations and technical challenges faced by x-ray CT technology are discussed. A comparison between 2D and 3D x-ray imaging capabilities is presented, and critical failure analysis case studies for first and second level interconnect that are hard or not possible to isolate by alternative methods are also discussed, as well as its unique progressive testing capability.
Keywords
X-ray imaging; computerised tomography; electronics packaging; failure analysis; X-ray imaging; critical failure analysis; high-resolution X-ray computed tomography; microelectronic packages; nondestructive failure analysis; Computed tomography; Image reconstruction; Image resolution; Microelectronics; Soldering; Three dimensional displays; X-ray imaging;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronic Components and Technology Conference (ECTC), 2011 IEEE 61st
Conference_Location
Lake Buena Vista, FL
ISSN
0569-5503
Print_ISBN
978-1-61284-497-8
Electronic_ISBN
0569-5503
Type
conf
DOI
10.1109/ECTC.2011.5898673
Filename
5898673
Link To Document