Humidity measurement by dynamic dew-point detection
Author :
Lang, W. ; Glosch, H. ; Billat, S. ; Querrioux, T. ; Kunze, M. ; Ashauer, M. ; Sandmaier, H.
Author_Institution :
HSG-IMIT, Schwenningen, Germany
Volume :
2
fYear :
2003
Firstpage :
1864
Abstract :
A new humidity measurement method is described. A thin membrane is cooled below the dew point temperature. Then it is rapidly heated. The heating curve (temperature versus time) gives the dew point and the amount of adsorbed water. The method is especially useful for the range of very high humidity, where most other methods are difficult to apply.
Keywords :
heat treatment; humidity measurement; membranes; temperature sensors; adsorbed water; dew point temperature; dynamic dew-point detection; heating curve; humidity measurement; thin membrane; Biomembranes; Equations; Heat transfer; Humidity measurement; Process control; Soil measurements; Temperature sensors; Thermal conductivity; Vehicle dynamics; Water heating;