Title :
Parametric model approach for rapid SAR measurements
Author :
Merckel, O. ; Bolomey, J.-Ch. ; Fleury, G.
Author_Institution :
Dept. of Electromagn. Res., SUPELEC, Gif-sur-Yvette, France
Abstract :
Specific absorption rate (SAR) designates the electromagnetic power density deposited per unit mass of biological tissues. This paper presents a new approach where SAR calculation for mobile phones is based on a parametric reconstruction of the E-field distribution in the phantom to assess rapid SAR measurements, by means of an ellipsoidal model. The estimation of its parameters is achieved by two ways: using a reduced number of real data points exclusively, and using a combination of real data points E-field extrapolation with a given expansion model.
Keywords :
dosimetry; electromagnetic fields; electromagnetic wave absorption; extrapolation; mobile handsets; E-field distribution; E-field extrapolation; biological tissues; dosimetry; electromagnetic power density; ellipsoidal model; mobile phones; parametric E-field reconstruction; parametric model approach; phaseless near-field technique; rapid SAR measurements; real data points; specific absorption rate; Biological tissues; Electromagnetic measurements; Imaging phantoms; Magnetic heads; Measurement standards; Mobile handsets; Parametric statistics; Position measurement; Specific absorption rate; Testing;