Integrated bio/chemical sensing system with a microfluidic transport module based on electrowetting
Author
Satoh, Wataru ; Hosono, Hiroki ; Suzuki, Hiroaki
Author_Institution
Graduate Sch. of Pure & Appl. Sci., Tsukuba Univ., Ibaraki, Japan
Volume
2
fYear
2005
Firstpage
1549
Abstract
An integrated micro analysis system was fabricated using a microfluidic transport system driven by electrowetting and an air-gap ammonia sensor. The basic element in the system was a row of elongated gold working electrodes and a protruding polydimethylsiloxane (PDMS) structure which form an open channel structure. The wettability of the gold electrode was changed by applying a negative potential with respect to a Ag/AgCl electrode, and a solution introduced from an inlet was mobilized through the gap between the working electrode and the protruding structure. Also, a solution could be transported to any desired directions without using any valves. Furthermore, two solutions could be mixed based on the same principle. The open structure of the flow channel facilitated the integration of an air-gap ammonia sensor. Ammonia diffused from the mixing area was detected as the potential change of a pH-indicator electrode. The 90% response time was 45 s for 10 mM ammonia. The relation between the potential of the pH-indicator electrode and the logarithm of ammonia concentration was linear. Furthermore, a biosensing system was constructed by using immobilized urease or creatinine deiminase and the ammonia sensor. The concentration of urea and creatinine could be determined by measuring ammonia produced enzymatically from a sample solution. Linear calibration plot was obtained for urea concentrations down to 100 μM and creatinine concentration down to 50 μM.
Keywords
ammonia; biosensors; channel flow; electrodes; gas sensors; microfluidics; wetting; 45 s; Ag-AgCl; PDMS structure; air-gap ammonia sensor; ammonia concentration; bio/chemical sensing system; biosensing system; creatinine deiminase; electrowetting; flow channel; gold working electrode; immobilized urease; integrated microanalysis system; microfluidic transport module; negative potential; open channel structure; pH-indicator electrode; polydimethylsiloxane structure; protruding structure; Air gaps; Biosensors; Chemical and biological sensors; Chemical elements; Delay; Electrodes; Gold; Microfluidics; Sensor systems; Valves;
fLanguage
English
Publisher
ieee
Conference_Titel
Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05. The 13th International Conference on
Print_ISBN
0-7803-8994-8
Type
conf
DOI
10.1109/SENSOR.2005.1497380
Filename
1497380
Link To Document