Abstract
Since the summer of 1997, three natural gas turbocompressors have been driven by adjustable speed supersynchronous motors of 38 MW @ 4200 rpm-the largest LCI drives ever built for that speed up to now. Restrictions on harmonics imposed by the utility, special network conditions, pressure by ecological political groups, and life-cycle economics were decisive in the choice of drive systems. Selection and design criteria for the drivers, network considerations, and first year positive operating experience are addressed by the client and the manufacturer. A subsequent project involving similar high speed electric motor drivers of 25 MW with active magnetic bearings for a “dry” turbocompressor string concludes the paper that primarily addresses prospective users of such systems
Keywords
DC-AC power convertors; compressors; gas turbines; invertors; magnetic bearings; synchronous motor drives; 25 MW; 38 MW; 50000 hp; active magnetic bearings; adjustable speed supersynchronous motors; dry turbocompressor string; harmonics restrictions; life-cycle economics; natural gas turbocompressors; operating experience; Electric motors; Environmental factors; Frequency; Magnetic levitation; Manufacturing; Natural gas; Power generation economics; Production; Reservoirs; Synchronous motors;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Conference, 2000. Conference Record of the 2000 IEEE
Conference_Location
Rome
ISSN
0197-2618
Print_ISBN
0-7803-6401-5
Type
conf
DOI
10.1109/IAS.2000.883211
Filename
883211
Link To Document