DocumentCode :
1738019
Title :
Evaluation of the insulation design of polymer housed surge arresters using salt-fog test
Author :
Biglar, B. ; Jayaram, S. ; Cherney, E.A.
Author_Institution :
Dept. of Electr. & Comput. Eng., Waterloo Univ., Ont., Canada
Volume :
1
fYear :
2000
fDate :
2000
Firstpage :
385
Abstract :
Insulation design of polymer housed surge arresters for distribution lines are evaluated by using IEC 1109 based salt fog test. The concept of “rest time” in salt fog tests of housings has been introduced with an effort to give fairness to silicone materials. The method provides a comprehensive evaluation of insulation design of polymer housed surge arresters. However, at this time, the inclusion of a rest time in salt-fog tests of silicone rubber housings is not warranted, as hydrophobicity did not recover completely even after a seven-day rest period
Keywords :
arresters; composite insulators; environmental testing; ethylene-propylene rubber; insulator testing; leakage currents; polymer insulators; silicone rubber insulators; IEC 1109 based test; average watt loss; distribution lines; hydrophobicity; insulation design; leakage current; polymer housed surge arresters; rest time concept; salt-fog test; silicone rubber housings; Arresters; IEC standards; Insulation testing; Insulator testing; Life testing; Materials testing; Plastic insulation; Polymers; Stress; Surges;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 2000 Annual Report Conference on
Conference_Location :
Victoria, BC
Print_ISBN :
0-7803-6413-9
Type :
conf
DOI :
10.1109/CEIDP.2000.885306
Filename :
885306
Link To Document :
بازگشت