DocumentCode :
1740589
Title :
Automatic measurements of the radius of curvature of the cornea in Slit Lamp
Author :
Ventura, Liliane ; Messias, Andre Macio Vieira ; Sousa, Sidney J Faria e
Author_Institution :
Lab. de Fisica Oftalmica-FMRP, SP, Brazil
Volume :
2
fYear :
2000
fDate :
2000
Firstpage :
864
Abstract :
We have developed an automatic optical system attached to the Slit Lamp in order to provide automatic measurements of the radius of curvature of the cornea at low cost. The system consists of projecting a light ring as a target at the patient´s cornea and the further analysis of the deformation of the target in order to obtain the radius of curvature as well as the axis of the associated astigmatism. The reflected image of the target is displayed in a PC´s monitor and a dedicated developed software performs the analysis of the image, that provides the corneal keratometry. Also, the system is able to measure irregular astigmatism and the clinician is able to understand the behavior of the cornea´s curvature radius in these regions by comparison of the graphical analysis of regular astigmatism that is generated by the software. There is no system commercially available which is able to measure irregular astigmatism, which is a very important feature for keratoconeous detection. The system is easy to use and it has a friendly software interface for the user. Measurements in volunteer patients have been made and the results that were obtained in the system, for the standard target ring, are in good agreement with commercial automatic and manual systems, presenting a correlation coefficient of 0,99347 and 0,97637, respectively regarding the radius of curvature and 0,96841 and 0,9568, respectively, regarding the axis. The system´s precision is 0,005 mm for the curvature radius and 2* for the axis component
Keywords :
biomedical measurement; eye; light reflection; optical microscopy; patient diagnosis; vision defects; PC monitor; Slit Lamp; astigmatism; automatic measurements; automatic optical system; axis component; clinician; cornea; corneal keratometry; correlation coefficient; dedicated developed software; deformation; friendly software interface; graphical analysis; irregular astigmatism; keratoconeous detection; light ring; low cost; manual systems; ocular biomicroscope; radius of curvature; reflected image; regular astigmatism; standard target ring; target; volunteer patients; Computer vision; Cornea; Costs; Image analysis; Lamps; Patient monitoring; Performance analysis; Software measurement; Software performance; Vision defects;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
ISSN :
1094-687X
Print_ISBN :
0-7803-6465-1
Type :
conf
DOI :
10.1109/IEMBS.2000.897853
Filename :
897853