• DocumentCode
    1740607
  • Title

    ECG and heart rate detection of prenatal cattle foetus using adaptive digital filtering

  • Author

    Chen, Wenxi ; Nemoto, Tetsu ; Kobayashi, Toshio ; Saito, Toshiyo ; Kasuya, Etsuko ; Hon, Yoshifumi

  • Author_Institution
    Fac. of Eng., Soka Univ., Tokyo, Japan
  • Volume
    2
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    962
  • Abstract
    A method for detecting the electrocardiogram and heart rate of prenatal cattle foetus is described. The foetal electrocardiogram is picked up from the body surface of a pregnant cow by disposable surface electrodes noninvasively. Using an adaptive digital filter, foetal ECG is enhanced from the corrupted measurement that is contaminated by maternal ECG. Foetal QRS complexes are detected from the enhanced foetal ECG by a digital matched filter. The heart rate is then calculated by known R-R intervals. The method was verified in nine pregnant cows with gestation period from 136 days to 224 days. The results showed that although it was difficult to monitor foetal heart rate from raw measured signal due to maternal ECG and EMG interferences, the proposed method was effective in detecting foetal ECG from the raw measurement mixing maternal and foetal signals. It is also noticed that the detected signal quality of a foetal ECG depends on the lead positions and gestation period. The method is considered useful in monitoring cattle´s health status in order to prevent premature birth, abortion and seize a symptom of apparent death
  • Keywords
    adaptive signal detection; electrocardiography; medical signal detection; obstetrics; veterinary medicine; 136 to 224 d; ECG detection; abortion; adaptive digital filter; adaptive digital filtering; apparent death; corrupted measurement; digital matched filter; disposable surface electrodes; electrodiagnostics; gestation period; heart rate detection; maternal ECG; pregnant cow body surface recordings; pregnant cows; premature birth; prenatal cattle foetus; raw measured signal; Cows; Digital filters; Electrocardiography; Electrodes; Fetus; Heart rate; Heart rate detection; Pollution measurement; Pregnancy; Surface contamination;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-6465-1
  • Type

    conf

  • DOI
    10.1109/IEMBS.2000.897881
  • Filename
    897881