DocumentCode :
1741727
Title :
Deep inspiration breath hold to reduce irradiated heart volume in breast cancer patients
Author :
Sixel, Katharina E. ; Aznar, Marianne C. ; Ung, Yee C.
Author_Institution :
Med. Phys. Dept., Toronto-Sunnybrook Regional Cancer Centre, Ont., Canada
Volume :
4
fYear :
2000
fDate :
2000
Firstpage :
2728
Abstract :
Adjuvant radiation therapy can significantly increase both disease-free and overall survival for breast cancer patients. However, long-term complications resulting from cardiac toxicity are a serious concern, especially for young patients with left-sided tumours. This issue becomes critical when patients are treated with wide tangents in order to include internal mammary nodes in the radiation field, thus increasing the amount of heart irradiated. The authors´ postulate is that deep inspiration breath hold will maximize the distance between chest wall and heart during tangential breast irradiation and will therefore minimize the irradiated cardiac volume. In this study, the Active Breath Control device (ABC) designed at William Beaumont Hospital, Michigan was used to quantify the potential effect of treating during breath hold for 5 left-sided breast cancer patients. This device forces breath hold at a predefined, reproducible lung volume. For each patient, two CT scans were acquired respectively with and without breath hold, and virtual simulation was performed for regular tangent and wide tangent techniques. The resulting dose volume histograms were calculated, and the volume of heart irradiated to 25 Gy or more was assessed. The authors´ results show that the use of the ABC can decrease the portion of irradiated heart from 6% to 1% if treating with regular tangents and from 16% to 4% with wide tangents in the most significant case. The methodology used and detailed results for the five patients will be presented in this feasibility study
Keywords :
cancer; cardiology; gynaecology; pneumodynamics; radiation therapy; 25 gray; CT scans; William Beaumont Hospital; active breath control device; adjuvant radiation therapy; breast cancer patients; cardiac complications; deep inspiration breath hold; disease-free survival; internal mammary nodes; irradiated heart volume reduction; overall survival; predefined reproducible lung volume; tangential breast irradiation; Biomedical applications of radiation; Breast cancer; Cardiac disease; Cardiovascular diseases; Heart; Hospitals; Lungs; Medical treatment; Tumors; Valves;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
ISSN :
1094-687X
Print_ISBN :
0-7803-6465-1
Type :
conf
DOI :
10.1109/IEMBS.2000.901423
Filename :
901423
Link To Document :
بازگشت