DocumentCode :
1744348
Title :
Influence of burner performance on SO/sub 3/ generation
Author :
Bogdan, Zelj Ko ; Schneider, Daniel Rolph
Author_Institution :
Fac. of Mech. Eng. & Naval Archit., Zagreb Univ., Croatia
fYear :
2000
fDate :
16-16 June 2000
Firstpage :
343
Lastpage :
349
Abstract :
Various impacts of the combustion process parameters on SO/sub 3/ generation in the steam generator furnace of the 210 MW oil-fired power plant Sisak have been studied by using mathematical modelling via the FLUENT/sup TM/ software package. The results of the simulation show that the excess combustion air of 1.07-1.10 cannot be decreased without modification of other combustion parameters because of soot appearance and increased CO concentration. By increasing the fuel atomising steam pressure, i.e. by decreasing the fuel droplet size to 50 /spl mu/m, the excess air is decreased to 1.035, which represents the upper limit of desired result. Thereby the average SO/sub 3/ concentration in flue gases is about 22 ppm.
Keywords :
boilers; combustion; digital simulation; furnaces; steam power stations; sulphur compounds; 210 MW; CO; CO concentration; FLUENT software package; SO/sub 3/; SO/sub 3/ generation; Sisak; burner performance; combustion parameters; combustion process parameters; excess combustion air; flue gases; fuel atomising steam pressure; fuel droplet; mathematical modelling; oil-fired power plant; soot appearance; steam generator furnace; Chemistry; Combustion; Corrosion; Equations; Fires; Flue gases; Fuels; Mathematical model; Power generation; Temperature;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Information Technology Interfaces, 2000. ITI 2000. Proceedings of the 22nd International Conference on
Conference_Location :
Pula, Croatia
ISSN :
1330-1012
Print_ISBN :
953-96769-1-6
Type :
conf
Filename :
915953
Link To Document :
بازگشت