DocumentCode :
1744390
Title :
PV hybrid VRLA battery test results from a telecommunications site
Author :
Hund, Thomas D. ; Stevens, John W.
Author_Institution :
Sandia Nat. Labs., Albuquerque, NM, USA
fYear :
2000
fDate :
2000
Firstpage :
1387
Lastpage :
1390
Abstract :
A new valve regulated lead-acid (VRLA) gel motive power battery and PV system power center have been tested in the laboratory and at a PV hybrid telecommunication site. The power center provides battery charge control, system remote communications, and data acquisition at the field test site. Extensive laboratory and field-test data were used to improve battery performance by optimizing regulation voltages, finish-charge, and system design. After 1.5-years of service, battery and charge controller performance have met all performance requirements for the remote communications site at Sandia National Laboratories
Keywords :
battery storage plants; lead acid batteries; photovoltaic power systems; power system measurement; solar cell arrays; telecommunication power supplies; 1.5 y; PV hybrid VRLA battery test results; PV power system; battery charge control; battery performance; battery storage; data acquisition; finish-charge; regulation voltages; telecommunications site; valve regulated lead-acid gel motive power battery; Batteries; Communication system control; Control systems; Data acquisition; Design optimization; Laboratories; System testing; Telecommunication control; Valves; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Photovoltaic Specialists Conference, 2000. Conference Record of the Twenty-Eighth IEEE
Conference_Location :
Anchorage, AK
ISSN :
0160-8371
Print_ISBN :
0-7803-5772-8
Type :
conf
DOI :
10.1109/PVSC.2000.916151
Filename :
916151
Link To Document :
بازگشت