DocumentCode :
1746367
Title :
Real time method to measure head disk spacing variation under vibration conditions
Author :
Li, Amei ; Liu, Xinqun ; Clegg, Warwick ; Jenkins, David ; Donnelly, Terry
Author_Institution :
Centre for Res. in Inf. Storage Technol., Plymouth Univ., UK
Volume :
2
fYear :
2001
fDate :
2001
Firstpage :
945
Abstract :
Three readback signal detection methods are presented for real-time head disk spacing variation measurement under vibration conditions. The proposed PW50 parameter estimation method is not restricted by the isolated readback pulse signal requirement, thus can be used for spacing variation measurement in normally operated hard disk drives, especially for low frequency variations. Amplitude detection and thermal signal detection methods, on the other side, are more effective for high frequency spacing variation measurement. Theoretical analysis and experimental results are given to illustrate the effectiveness of the methods
Keywords :
disc drives; distance measurement; hard discs; height measurement; parameter estimation; signal detection; vibrations; PW50 parameter estimation method; amplitude detection method; flying height variation; hard disk drives; head disk spacing variation; high frequency spacing variations; low frequency spacing variations; readback signal detection methods; real time method; spacing variation measurement; thermal signal detection method; vibration conditions; Disk recording; Frequency measurement; Hard disks; Magnetic heads; Magnetic recording; Magnetic separation; Parameter estimation; Pulse measurements; Signal detection; Vibration measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference, 2001. IMTC 2001. Proceedings of the 18th IEEE
Conference_Location :
Budapest
ISSN :
1091-5281
Print_ISBN :
0-7803-6646-8
Type :
conf
DOI :
10.1109/IMTC.2001.928218
Filename :
928218
Link To Document :
بازگشت