Abstract
This category of continuous level sensors is related to the float type. An angular-position transducer is used to indicate the number of turns of a drum as a plumb line wound on the drum is unwound until a weight (for solids) or a float (for fluids) touches the surface. When this occurs the plumb line loses tension, a tension sensor (force transducer) detects the loss in tension and sends a signal to a direction-changing device, that controls a drum drive motor. Operating variables play a major role in determining accuracy and repeatability requirements. The paper presents a dynamic analysis and identification of the sensor system to increase static and dynamic accuracy
Keywords
analogue processing circuits; dynamic response; equivalent circuits; force sensors; level measurement; analog equivalent circuit; angular-position transducer; continuous level sensors; direction-changing device; drum drive motor; dynamic accuracy; dynamic analysis; force transducer; plumb-line-type liquid level measurement system; repeatability; sensor system identification; static accuracy; tension sensor; Atmospheric measurements; Circuits; Control systems; Electric variables measurement; Length measurement; Level control; Level measurement; Pulse measurements; Transducers; World Wide Web;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference, 2001. IMTC 2001. Proceedings of the 18th IEEE
Conference_Location
Budapest
ISSN
1091-5281
Print_ISBN
0-7803-6646-8
Type
conf
DOI
10.1109/IMTC.2001.928305
Filename
928305
Link To Document