• DocumentCode
    1746422
  • Title

    Dynamic analysis of plumb-line-type liquid level measurement system

  • Author

    Fock, Károly ; Fock, Balázs

  • Author_Institution
    Dept. of Control Eng. & Inf. Technol., Budapest Univ. of Technol. & Econ., Hungary
  • Volume
    2
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    1406
  • Abstract
    This category of continuous level sensors is related to the float type. An angular-position transducer is used to indicate the number of turns of a drum as a plumb line wound on the drum is unwound until a weight (for solids) or a float (for fluids) touches the surface. When this occurs the plumb line loses tension, a tension sensor (force transducer) detects the loss in tension and sends a signal to a direction-changing device, that controls a drum drive motor. Operating variables play a major role in determining accuracy and repeatability requirements. The paper presents a dynamic analysis and identification of the sensor system to increase static and dynamic accuracy
  • Keywords
    analogue processing circuits; dynamic response; equivalent circuits; force sensors; level measurement; analog equivalent circuit; angular-position transducer; continuous level sensors; direction-changing device; drum drive motor; dynamic accuracy; dynamic analysis; force transducer; plumb-line-type liquid level measurement system; repeatability; sensor system identification; static accuracy; tension sensor; Atmospheric measurements; Circuits; Control systems; Electric variables measurement; Length measurement; Level control; Level measurement; Pulse measurements; Transducers; World Wide Web;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 2001. IMTC 2001. Proceedings of the 18th IEEE
  • Conference_Location
    Budapest
  • ISSN
    1091-5281
  • Print_ISBN
    0-7803-6646-8
  • Type

    conf

  • DOI
    10.1109/IMTC.2001.928305
  • Filename
    928305