DocumentCode :
17474
Title :
Comparison of Wound-Field Switched-Flux Machines
Author :
Zhou, Y.J. ; Zhu, Z.Q.
Author_Institution :
Dept. of Electron. & Electr. Eng., Univ. of Sheffield, Sheffield, UK
Volume :
50
Issue :
5
fYear :
2014
fDate :
Sept.-Oct. 2014
Firstpage :
3314
Lastpage :
3324
Abstract :
This paper proposes a three-phase wound-field switched-flux (WFSF) machine. It is found that this machine has much higher average torque compared with the conventional 12-slot/8-pole machine with a segmented rotor and 12-slot/5-pole WFSF machine under the constraint of the same copper loss. All of those machines have been optimized to achieve the maximum torque for comparison. The performances of four machines, including back electromotive force, cogging torque, and static torque, are analyzed and compared by 2-D finite-element analysis and validated by experiments on the prototype machines.
Keywords :
finite element analysis; rotors; synchronous machines; torque; 12-slot 5-pole WFSF machine; 12-slot 8-pole machine; 2D finite element analysis; back electromotive force; cogging torque; copper loss; static torque; synchronous machines; three-phase wound-field switched-flux machine; Coils; Copper; Rotors; Stator windings; Torque; Windings; Machine windings; switched-flux (SF) machines; synchronous machine; wound-field machines;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/TIA.2014.2309726
Filename :
6755543
Link To Document :
بازگشت