Vibration amplitude distribution measurements on piezoelectric PZT/glass composite transducers for ultrasonic bio-cell filters
Author
Benes, E. ; Frank, A. ; Böhm, H. ; Gröschl, M. ; Trampler, F. ; Burger, W. ; Nowotny, H.
Author_Institution
Inst. fur Allgemeine Phys., Technische Univ. Wien, Austria
Volume
1
fYear
2000
fDate
2000
Firstpage
23
Abstract
The typical out-of-plane vibration amplitude distributions associated with the various piezoelectrically excitable resonance frequencies of PZT/glass composite resonators have been measured systematically by use of a specially developed scanning LDV vibration amplitude measurement system. The corresponding vibration modes have been identified and characterized, the influence of the lateral boundary conditions is demonstrated. The presented results are of importance for state of the art design of acoustic cell filters recently launched at the biotechnology market
Keywords
biological techniques; cellular biophysics; filtration; lead compounds; piezoelectric transducers; ultrasonic transducers; vibration measurement; PZT; PbZrO3TiO3; lateral boundary conditions; piezoelectric PZT/glass composite transducer; resonant frequency; scanning LDV measurement system; ultrasonic bio-cell filter; vibration amplitude distribution; Acoustic measurements; Electric variables measurement; Glass; Piezoelectric transducers; Resonance; Resonant frequency; Resonator filters; Ultrasonic transducers; Ultrasonic variables measurement; Vibration measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Applications of Ferroelectrics, 2000. ISAF 2000. Proceedings of the 2000 12th IEEE International Symposium on
Conference_Location
Honolulu, HI
ISSN
1099-4734
Print_ISBN
0-7803-5940-2
Type
conf
DOI
10.1109/ISAF.2000.941505
Filename
941505
Link To Document