• DocumentCode
    1751995
  • Title

    Performance of the light trigger system in the liquid xenon gamma-ray imaging telescope LXeGRIT

  • Author

    Oberlack, Uwe ; Aprile, Elena ; Curioni, Alessandro ; Giboni, Karl-Ludwig

  • Author_Institution
    Astrophys. Lab., Columbia Univ., New York, NY, USA
  • Volume
    1
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    27851
  • Abstract
    LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics, based on a liquid xenon time projection chamber with charge and light readout. The energy and direction of an incident gamma-ray is reconstructed from the three-dimensional locations and energy deposits of individual interactions taking place in the homogeneous detector volume. While the charge signals provide energy information and X-Y-positions, the fast xenon scintillation light signal is used to trigger the detector. The drift time measurement, referred to the time of the trigger signal, gives the Z-position with the known drift velocity. The light is detected by four UV-sensitive photomultiplier tubes (PMTs). The logical OR of the PMT signals triggers the data acquisition system with an efficiency which depends on the event energy and location, as well as on the discriminator thresholds used on the individual PMTs. Results from experiments with a tagged 22Na source give the spatial distribution of the light trigger efficiency for 511 keV gamma-rays. When averaged over the whole sensitive volume and all PMTs, the trigger efficiency is 47% or 40% for two discriminator windows used during the LXeGRIT balloon flight of 1999. These values are strongly affected by the different sensitivity of each PMT. The corresponding average efficiency at 511 keV for the best of the four PMTs is in fact 63%, and approaches 100% for interactions taking place in a small volume right above the PMT
  • Keywords
    astronomical telescopes; liquid scintillation detectors; position sensitive particle detectors; time projection chambers; 1 MeV; 511 keV; 22Na source; Compton telescope; LXeGRIT; Xe; drift time; drift velocity; gamma-ray astrophysics; gamma-ray imaging telescope; light trigger system; liquid Xe; photomultiplier tubes; time projection chamber; Astrophysics; Data acquisition; Electron mobility; Gamma ray detection; Gamma ray detectors; Photomultipliers; Solid scintillation detectors; Telescopes; Time measurement; Xenon;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2000 IEEE
  • Conference_Location
    Lyon
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-6503-8
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2000.949052
  • Filename
    949052