  • Abstract
    In this DoE (design of experiment) study, we reported a relatively simple methodology which enables Aleris VUVSE system to well maintain the thickness and nitrogen content (N%) measurement accuracy and matching of DPN, pre and post PM (preventive maintenance) of system, via rely on monitoring of the aged/non-annealed nitrided oxide samples N% correlation function, without the need to rely on the standard XPS referencing targets.
  • Keywords
    preventive maintenance; semiconductor industry; Aleris VUVSE system; N% recovery post PM; aged SPA oxynitride gate; design of experiment; nitrogen content; nonannealed SPA oxynitride gate; preventive maintenance; Aging; Correlation; Nitrogen; Thickness measurement;