Title :
Radial modulation contrast imaging using a 20-mhz single-element intravascular ultrasound catheter
Author :
Yu, Francois T. H. ; Villanueva, Flordeliza S. ; Xucai Chen
Author_Institution :
Center for Ultrasound Mol. Imaging & Therapeutics, Univ. of Pittsburgh, Pittsburgh, PA, USA
Abstract :
Contrast-enhanced intravascular ultrasound imaging is a promising tool for the characterization of coronary vasa vasorum proliferation, which has been identified as a marker of, and possible etiologic factor in, the development of high-risk atherosclerotic plaques. Resonance-based nonlinear detection methods have required the development of prototype catheters which are not commercially available, thus limiting clinical translation. In this study, we investigated the performances of a radial modulation imaging approach (25/3 MHz combination) using simulations, implemented it on a clinical 20-MHz rotating catheter, and tested it in a wall-less tissue-mimicking flow phantom perfused with lipid-encapsulated microbubbles (MBs). The effects of the phase lag, low-frequency pressure, and MB concentration on the envelope subtracted radial modulation signals were investigated as a function of depth. Our dual-pulse dual-frequency approach produced contrast-specific images with contrast-to-tissue improvements over B-mode of 15.1 ± 2.1 dB at 2 mm and 6.8 ± 0.1 dB at 4 mm depths. Using this imaging strategy, 200 μm-diameter cellulose tubing perfused with MBs could be resolved while surrounding tissue scattering was suppressed. These results raise promise for the detection of coronary vasa vasorum and may ultimately facilitate the detection of plaque at risk for rupture.
Keywords :
biomedical ultrasonics; blood vessels; bubbles; cardiovascular system; catheters; haemodynamics; medical disorders; phantoms; B-mode; MB concentration; cellulose tubing; clinical rotating catheter; clinical translation; contrast-enhanced intravascular ultrasound imaging; contrast-to-tissue improvement; coronary vasa vasorum detection; coronary vasa vasorum proliferation characterization; depth 2 mm; depth 4 mm; depth function; dual-pulse dual-frequency approach; envelope subtracted radial modulation signals; etiologic factor; frequency 20 MHz; high-risk atherosclerotic plaques; imaging strategy; lipid-encapsulated microbubbles; low-frequency pressure; marker; phase lag; plaque detection; prototype catheter development; radial modulation contrast imaging; resonance-based nonlinear detection method; rupture risk; single-element intravascular ultrasound catheter; size 200 mum; surrounding tissue scattering; wall-less tissue-mimicking flow phantom; Catheters; Delays; Imaging; Scattering; Sociology; Statistics; Ultrasonic imaging;
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
DOI :
10.1109/TUFFC.2014.2970