DocumentCode :
1761802
Title :
Improved Pulse Wave Velocity Estimation Using an Arterial Tube-Load Model
Author :
Mingwu Gao ; Guanqun Zhang ; Olivier, N. Bari ; Mukkamala, R.
Author_Institution :
Dept. of Electr. & Comput. Eng., Michigan State Univ., East Lansing, MI, USA
Volume :
61
Issue :
3
fYear :
2014
fDate :
41699
Firstpage :
848
Lastpage :
858
Abstract :
Pulse wave velocity (PWV) is the most important index of arterial stiffness. It is conventionally estimated by noninvasively measuring central and peripheral blood pressure (BP) and/or velocity (BV) waveforms and then detecting the foot-to-foot time delay between the waveforms wherein wave reflection is presumed absent. We developed techniques for improved estimation of PWV from the same waveforms. The techniques effectively estimate PWV from the entire waveforms, rather than just their feet, by mathematically eliminating the reflected wave via an arterial tube-load model. In this way, the techniques may be more robust to artifact while revealing the true PWV in absence of wave reflection. We applied the techniques to estimate aortic PWV from simultaneously and sequentially measured central and peripheral BP waveforms and simultaneously measured central BV and peripheral BP waveforms from 17 anesthetized animals during diverse interventions that perturbed BP widely. Since BP is the major acute determinant of aortic PWV, especially under anesthesia wherein vasomotor tone changes are minimal, we evaluated the techniques in terms of the ability of their PWV estimates to track the acute BP changes in each subject. Overall, the PWV estimates of the techniques tracked the BP changes better than those of the conventional technique (e.g., diastolic BP root-mean-squared errors of 3.4 versus 5.2 mmHg for the simultaneous BP waveforms and 7.0 versus 12.2 mmHg for the BV and BP waveforms (p <; 0.02)). With further testing, the arterial tube-load model-based PWV estimation techniques may afford more accurate arterial stiffness monitoring in hypertensive and other patients.
Keywords :
biomechanics; blood pressure measurement; blood vessels; patient monitoring; physiological models; acute BP changes; anesthetized animals; arterial stiffness monitoring; arterial tube-load model-based PWV estimation techniques; central BV waveforms; central blood pressure waveforms; hypertensive patients; noninvasive measurement; peripheral BP waveforms; peripheral blood pressure waveforms; pulse wave velocity estimation; simultaneous measurement; vasomotor tone; velocity waveforms; wave reflection; Animals; Arteries; Biomedical measurement; Electron tubes; Foot; Reflection; Transfer functions; Arterial stiffness; blood pressure (BP); blood velocity; pulse transit time (PTT); pulse wave velocity (PWV); transfer function;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2013.2291385
Filename :
6668883
Link To Document :
بازگشت