DocumentCode :
1761812
Title :
Equivalent Input Magnetic Noise Analysis for the Induction Magnetometer of 0.1 mHz to 1 Hz
Author :
Bin Yan ; Wanhua Zhu ; Leisong Liu ; Kai Liu ; Guangyou Fang
Author_Institution :
Univ. of Chinese Acad. of Sci., Beijing, China
Volume :
14
Issue :
12
fYear :
2014
fDate :
Dec. 2014
Firstpage :
4442
Lastpage :
4449
Abstract :
Induction magnetometer (IM) is the transducer for measuring the magnetic field´s variations, which is widely used in space research, geophysical exploration, and so on. Among all kinds of IMs, IMs of 0.1 mHz to 1 Hz with negative feedback flux and chopper stabilized amplifiers are especially popular used for the magnetotelluric method in geophysical explorations. In this paper, the equivalent input magnetic noise (EIMN) of IMs of 0.1 mHz to 1 Hz is discussed and modeled. Seven main noise sources are described, numerical evaluated, and experimental modeled separately. At last, an experimental IM is built and its EIMN is measured low to 0.1 mHz to confirm the theoretical model.
Keywords :
electromagnetic induction; magnetic noise; magnetometers; equivalent input magnetic noise; equivalent input magnetic noise analysis; frequency 0.1 mHz to 1 Hz; induction magnetometer; noise sources; quasiDC frequency band; 1f noise; Choppers (circuits); Coils; Frequency measurement; Magnetic field measurement; Resistance; 1/f noise; Induction magnetometer; noise model; quasi-DC frequency band;
fLanguage :
English
Journal_Title :
Sensors Journal, IEEE
Publisher :
ieee
ISSN :
1530-437X
Type :
jour
DOI :
10.1109/JSEN.2014.2336971
Filename :
6857340
Link To Document :
بازگشت