DocumentCode :
1763095
Title :
Real-Time and Offline Performance of Pattern Recognition Myoelectric Control Using a Generic Electrode Grid With Targeted Muscle Reinnervation Patients
Author :
Tkach, Dennis C. ; Young, Aaron J. ; Smith, Lauren H. ; Rouse, Elliott J. ; Hargrove, Levi J.
Author_Institution :
Center for Bionic Med., Rehabilitation Inst. of Chicago, Chicago, IL, USA
Volume :
22
Issue :
4
fYear :
2014
fDate :
41821
Firstpage :
727
Lastpage :
734
Abstract :
Targeted muscle reinnervation (TMR) is a surgical technique that creates myoelectric prosthesis control sites for high-level amputees. The electromyographic (EMG) signal patterns provided by the reinnervated muscles are well-suited for pattern recognition control. Pattern recognition allows for control of a greater number of degrees of freedom (DOF) than the conventional, EMG amplitude-based approach. Previous pattern recognition studies have shown benefit in placing electrodes directly over the reinnervated muscles. Localizing the optimal TMR locations is inconvenient and time consuming. In this contribution, we demonstrate that a clinically practical grid arrangement of electrodes yields real-time control performance that is equivalent to, or better than, the site-specific electrode placement for simultaneous control of multiple DOFs using pattern recognition. Additional findings indicate that grid-like electrode arrangement yields significantly lower classification errors for classifiers with a large number of movement classes (>9). These findings suggest that a grid electrode arrangement can be effectively used to control a multi-DOF upper limb prosthesis while reducing the time and effort associated with fitting the prosthesis due to clinical localization of control sites on amputee patients.
Keywords :
biomedical electrodes; electromyography; medical control systems; medical signal processing; muscle; pattern recognition; prosthetics; real-time systems; surgery; EMG amplitude-based approach; EMG signal patterns; degrees of freedom; electromyographic signal patterns; generic electrode grid; grid-like electrode arrangement; low classification errors; multiDOF upper limb prosthesis; multiple DOF; myoelectric prosthesis control sites; pattern recognition myoelectric control; real-time control performance; real-time-offline performance; simultaneous control; site-specific electrode placement; surgical technique; targeted muscle reinnervation patients; Elbow; Electrodes; Electromyography; Muscles; Pattern recognition; Prosthetics; Real-time systems; Electrode grid; electromyography (EMG) prosthesis control; pattern recognition; targeted muscle reinnervation; upper limb amputee;
fLanguage :
English
Journal_Title :
Neural Systems and Rehabilitation Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
1534-4320
Type :
jour
DOI :
10.1109/TNSRE.2014.2302799
Filename :
6737321
Link To Document :
بازگشت