DocumentCode :
1763307
Title :
Development of a Portable ^{10}{\\hbox {B}} -Based ^{3}{\\hbox {He}} Replacement Neutron Det
Author :
King, M.J. ; Gozani, T. ; Benetti, R. ; Hilliard, D.B. ; Benetti, B.
Author_Institution :
Rapiscan Labs., Sunnyvale, CA, USA
Volume :
60
Issue :
2
fYear :
2013
fDate :
41365
Firstpage :
885
Lastpage :
889
Abstract :
Rapiscan Laboratories and Helicon Thin Film Systems have designed and developed a detector for the replacement of 3He-based detector modules. Our neutron detector consists of a thinly coated 10B flat-panel ionization chamber that can be deployed as a direct drop-in replacement for current RPM 3He detectors. The uniqueness of our approach in providing a large-area detector is the simplicity of construction, scalability of the unit cell detector, ease of adaptability to a variety of applications, and low cost. In the initial development, a smaller area, multi-layer prototype natB4C-based ionization chamber was built and tested, demonstrating neutron detection capability and gamma-ray insensitivity. In the subsequent stage of detector development, enriched 10B8C films were robustly deposited, passed temperature cycling testing, and were tested in the prototype chamber for neutron sensitivity. In addition to the development of the boron-coated substrates, a complete signal processing circuit, which includes a preamplifier, amplifier, and discriminator, was fabricated on a circuit board and tested within the prototype chamber. Currently, a portable detector has been tested.
Keywords :
discriminators; ionisation chambers; neutron detection; nuclear electronics; portable instruments; preamplifiers; printed circuits; sensitivity; signal processing equipment; 3He-based detector modules; RPM 3He detector; boron-coated substrates; cell detector; circuit board; direct drop-in replacement; discriminator; enriched 10B4C films; gamma-ray insensitivity; helicon thin film systems; large-area detector; multilayer prototype natB4C-based ionization chamber; neutron sensitivity; portable 10B-based 3He replacement neutron detector; preamplifier; prototype chamber; signal processing circuit; temperature cycling testing; thin-coated 10B flat-panel ionization chamber; Detectors; Neutrons; Noise; Polyethylene; Prototypes; Sensitivity; Substrates; 3-He replacement; Boron-10; ionization chamber; neutron detector;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2013.2246579
Filename :
6482276
Link To Document :
بازگشت