Abstract :
This study aims to experimentally investigate the impact of vessel stiffness on the flow dynamics of pulsatile vascular flow. Vessel phantoms with elastic walls were fabricated using polyvinyl alcohol cryogel to result in stiffness ranging from 60.9 to 310.3 kPa and tested with pulsatile flows using a flow circulation set-up. Two-dimensional instantaneous and time-dependent flow velocity and shear rate vector fields were measured using ultrasonic particle image velocimetry (EchoPIV). The waveforms of peak velocities measured by EchoPIV were compared with the ultrasonic pulse Doppler spectrum, and the measuring accuracy was validated. The cyclic vessel wall motion and flow pressure were obtained as well. The results showed that vessel stiffening influenced the waveforms resulting from vessel wall distension and flow pressure, and the fields of flow velocity and shear rate. The stiffer vessel had smaller inner diameter variation, larger pulse pressure and median pressure. The velocity and shear rate maximized at peak systole for all vessels. The results showed a decrease in wall shear stress for a stiffer vessel, which can initiate the atherosclerotic process. Our study elucidates the impact of vessel stiffness on several flow dynamic parameters, and also demonstrates the EchoPIV technique to be a useful and powerful tool in cardiovascular research.
Keywords :
biomedical ultrasonics; blood vessels; flow visualisation; haemodynamics; phantoms; pulsatile flow; atherosclerotic process; cyclic vessel wall motion; elastic walls; flow dynamics; flow pressure; polyvinyl alcohol cryogel; pulsatile vascular flow; shear rate vector fields; time-dependent flow velocity; two-dimensional instantaneous flow; ultrasonic particle image velocimetry technique; ultrasonic pulse Doppler spectrum; vessel phantoms; vessel stiffness; vessel wall distension; Acoustics; Biomedical measurement; Blood flow; Phantoms; Ultrasonic imaging; Ultrasonic variables measurement; Velocity measurement; Flow velocity; polyvinyl alcohol (PVA) cryogel; shear rate; ultrasonic particle image velocimetry; vessel stiffness;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2014.2320443
Filename :
6808483
Link To Document :
بازگشت