DocumentCode
1764652
Title
Accurate NHIF Locator Utilizing Two-End Unsynchronized Measurements
Author
Ghazizadeh-Ahsaee, Mahdi
Author_Institution
Electr. Eng. Dept., Univ. of Zabol, Zabol, Iran
Volume
28
Issue
1
fYear
2013
fDate
Jan. 2013
Firstpage
419
Lastpage
426
Abstract
In this paper, an accurate fault locator is proposed for nonlinear high impedance faults (NHIFs) based on unsynchronized data gathered from both ends of the transmission line. This method is independent of the fault type, impedance, configuration, and two-end Thevenin´s equivalent impedances of the external networks. The distributed parameter line model in the time domain is considered in the new algorithm which accurately models the transmission line. The location of fault and synchronization time are calculated by solving an optimization problem. The performance of the algorithm is tested for different synchronization times and various fault conditions. The performed evaluation shows the validity of the developed fault locator and its accuracy while NHIFs occur.
Keywords
electric impedance; fault location; optimisation; power transmission faults; power transmission lines; synchronisation; time-domain analysis; NHIF fault locator; Thevenin equivalent impedance; distributed parameter line model; fault type; nonlinear high impedance fault; optimization; synchronization time; time domain analysis; transmission line; unsynchronized measurement; Equations; Impedance; Mathematical model; Optimization; Power transmission lines; Synchronization; Transmission line measurements; Fault locator; nonlinear high impedance faults (NHIFs); synchronization time; time domain;
fLanguage
English
Journal_Title
Power Delivery, IEEE Transactions on
Publisher
ieee
ISSN
0885-8977
Type
jour
DOI
10.1109/TPWRD.2012.2215889