• DocumentCode
    1765015
  • Title

    Single-sensor maximum power point tracking algorithms

  • Author

    Urayai, Caston ; Amaratunga, G.A.J.

  • Author_Institution
    Eng. Dept., Cambridge Univ., Cambridge, UK
  • Volume
    7
  • Issue
    1
  • fYear
    2013
  • fDate
    41306
  • Firstpage
    82
  • Lastpage
    88
  • Abstract
    Single-sensor maximum power point tracking algorithms for photovoltaic systems are presented. The algorithms have the features, characteristics and advantages of the widely used incremental conductance (INC) algorithm. However; unlike the INC algorithm which requires two sensors (the voltage sensor and the current sensor), the single-sensor algorithms are more desirable because they require only one sensor: the voltage sensor. The algorithms operate by maximising power at the DC-DC converter output, instead of the input.
  • Keywords
    DC-DC power convertors; electric sensing devices; maximum power point trackers; photovoltaic power systems; DC-DC converter; INC algorithm; current sensor; incremental conductance algorithm; photovoltaic system; single-sensor maximum power point tracking algorithm; voltage sensor;
  • fLanguage
    English
  • Journal_Title
    Renewable Power Generation, IET
  • Publisher
    iet
  • ISSN
    1752-1416
  • Type

    jour

  • DOI
    10.1049/iet-rpg.2011.0264
  • Filename
    6483184