• DocumentCode
    1766135
  • Title

    Bayesian Approach to Dynamically Controlling Data Collection in P300 Spellers

  • Author

    Throckmorton, C.S. ; Colwell, K.A. ; Ryan, D.B. ; Sellers, E.W. ; Collins, Leslie M.

  • Author_Institution
    Electr. & Comput. Eng. Dept., Duke Univ., Durham, NC, USA
  • Volume
    21
  • Issue
    3
  • fYear
    2013
  • fDate
    41395
  • Firstpage
    508
  • Lastpage
    517
  • Abstract
    P300 spellers provide a noninvasive method of communication for people who may not be able to use other communication aids due to severe neuromuscular disabilities. However, P300 spellers rely on event-related potentials (ERPs) which often have low signal-to-noise ratios (SNRs). In order to improve detection of the ERPs, P300 spellers typically collect multiple measurements of the electroencephalography (EEG) response for each character. The amount of collected data can affect both the accuracy and the communication rate of the speller system. The goal of the present study was to develop an algorithm that would automatically determine the necessary amount of data to collect during operation. Dynamic data collection was controlled by a threshold on the probabilities that each possible character was the target character, and these probabilities were continually updated with each additional measurement. This Bayesian technique differs from other dynamic data collection techniques by relying on a participant-independent, probability-based metric as the stopping criterion. The accuracy and communication rate for dynamic and static data collection in P300 spellers were compared for 26 users. Dynamic data collection resulted in a significant increase in accuracy and communication rate.
  • Keywords
    Bayes methods; bioelectric potentials; brain-computer interfaces; electroencephalography; handicapped aids; medical signal processing; muscle; neurophysiology; signal classification; Bayesian approach; EEG; P300 spellers; brain-computer interface; communication aids; dynamic data collection control; electroencephalography; event-related potentials; multiple measurement collection; neuromuscular disabilities; noninvasive method; participant-independent metrics; probability-based metrics; signal classification; signal-to-noise ratio; stopping criterion; Accuracy; Bit rate; Classification algorithms; Data collection; Educational institutions; Electroencephalography; Training data; Brain-computer interface; P300 speller; dynamic stopping; Algorithms; Bayes Theorem; Brain-Computer Interfaces; Communication Aids for Disabled; Database Management Systems; Databases, Factual; Diagnosis, Computer-Assisted; Event-Related Potentials, P300; Humans; Information Storage and Retrieval; Male; Pattern Recognition, Automated; Task Performance and Analysis; Young Adult;
  • fLanguage
    English
  • Journal_Title
    Neural Systems and Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1534-4320
  • Type

    jour

  • DOI
    10.1109/TNSRE.2013.2253125
  • Filename
    6484184