• DocumentCode
    1766744
  • Title

    Magnetic Injection of Nanoparticles Into Rat Inner Ears at a Human Head Working Distance

  • Author

    Sarwar, Azeem ; Lee, Roger ; Depireux, Didier A. ; Shapiro, Benjamin

  • Author_Institution
    Fischell Dept. of Bioeng., Univ. of Maryland, College Park, MD, USA
  • Volume
    49
  • Issue
    1
  • fYear
    2013
  • fDate
    Jan. 2013
  • Firstpage
    440
  • Lastpage
    452
  • Abstract
    Due to the physics of magnetic fields and forces, any single magnet will always attract or pull-in magnetically-responsive particles. However, there are a variety of clinical needs where it is advantageous to be able to push away or `magnetically inject´ therapeutic particles. Here we focus on magnetic injection to treat inner-ear diseases. The inner ear is behind the blood-ear barrier, meaning, blood vessels that supply blood to the inner ear have vessel walls that are impermeable and prevent drugs from exiting the vessels and reaching inner ear tissues. In our prior work, we showed that a simple four-magnet system could successfully push nanoparticles from the middle into the inner ear, thus circumventing the blood-ear barrier. That first-generation system could only push at a 2 cm distance: a range sufficient for rat experiments but not appropriate for adult human patients whose face-to-middle-ear distance varies from 3 to 5 cm. Here we demonstrate an optimal two-magnet system that can push at 3 to 5 cm distances. The system is designed using semi-definite quadratic programming which guarantees a globally optimal magnet configuration, is fabricated, characterized in detail, compared to theory, and then tested in rat experiments but now at a human 4 cm working distance.
  • Keywords
    drug delivery systems; ear; magnetic particles; medical computing; nanomedicine; nanoparticles; quadratic programming; blood-ear barrier; distance 3 cm to 5 cm; inner ear disease treatment; magnetic injection; magnetic nanoparticles; magnetically responsive particles; optimal magnet configuration; optimal two magnet system; rat inner ears; semidefinite quadratic programming; therapeutic particles; working distance; Drugs; Ear; Force; Humans; Magnetic domains; Magnetization; Nanoparticles; Halbach magnet design; inner ear; magnetic nanoparticles; magnetic pushing;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.2012.2221456
  • Filename
    6392415