Failure analysis for electromagnetic relay contacts adhesion by using XES
Author
Cheng Gao ; Chengcheng Fu ; Jiaoying Huang ; Sicong Hu
Author_Institution
Sch. of Reliability & Syst. Eng., Beihang Univ., Beijing, China
fYear
2014
fDate
24-27 Aug. 2014
Firstpage
97
Lastpage
101
Abstract
Failure analysis is a vital tool used in the development of new products and for the improvement of existing products. And electromagnetic relay is indispensable and widely used in automatic electrical system, which has complex special structure and every component might fail. The failure analysis for electromagnetic relay have a series of methods applying for a number of failure models. The different failure models and failure mechanism of electromagnetic relay have been listed. Then a failure analysis process is proposed for the most common one, contacts adhesion. X-ray emission spectroscopy test is an important step in this process. It can help to observe more detail about morphology. After theoretical analysis, an actual case of failure analysis for electromagnetic relay contacts adhesion by using XES is presented, showing the feasibility and validity of the process. The failure mechanism is also analyzed. At last, some suggestions for improving reliability and avoiding contacts adhesion are given.
Keywords
X-ray emission spectra; adhesion; electrical contacts; failure analysis; reliability; X-ray emission spectroscopy test; XES; automatic electrical system; electromagnetic relay contact adhesion reliability; failure analysis process; Adhesives; Contacts; Electromagnetics; Failure analysis; Relays; Reliability; Surface morphology; XES; contacts; electromagnetic relay; failure analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Prognostics and System Health Management Conference (PHM-2014 Hunan), 2014
Conference_Location
Zhangiiaijie
Print_ISBN
978-1-4799-7957-8
Type
conf
DOI
10.1109/PHM.2014.6988141
Filename
6988141
Link To Document