Title :
Analysis of hysteresis and eddy-current losses for a medium-frequency transformer in an isolated DC-DC converter
Author :
Nakahara, Mizuki ; Wada, Kazuyoshi
Author_Institution :
Dept. of Electr. & Electron. Eng., Tokyo Metropolitan Univ., Hachioji, Japan
Abstract :
Recently, because of the rapid development of power devices, high-power isolated DC-DC converters using medium-frequency (MF) transformers have been proposed. In order to realize a high-power-density isolated DC-DC converter, it is important to analyze losses of the transformers because the volume of the MF transformer is one of the large parts in the DC-DC converter. In this paper, a procedure for separating the iron loss into hysteresis and eddy-current losses is presented. The validity of the separation procedure is then considered by comparing the calculation results with the results of the analysis method. Furthermore, the temperature dependencies of the iron loss will be considered by the experiments.
Keywords :
DC-DC power convertors; eddy currents; hysteresis; power transformers; eddy-current losses; high-power isolated DC-DC converters; hysteresis analysis; medium-frequency transformer; Equations; Iron;
Conference_Titel :
Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE-ASIA), 2014 International
Conference_Location :
Hiroshima
DOI :
10.1109/IPEC.2014.6869942