Title :
An investigation of calibration approaches to RS105 test system of MIL-STD-461
Author :
Lijun Yao ; Feng Zhang ; Dong Liu ; Hongliang Sun ; Tao Shen ; Ning Kang ; Jianling Huang
Author_Institution :
Electromagn. Environ. Effect Lab., Beijing Inst. of Radio Metrol. & Meas., Beijing, China
Abstract :
MIL-STD-461 has been applied and adapted as the basis for electromagnetic interference standards in many countries. By investigating the different versions of MIL-STD-461/462 in this paper, it can be found that the requirement and procedure of system calibration of RS105 test are more and more specific and comprehensive. Some problems are also discussed subsequently in the application of the calibration method of the current valid version of MIL-STD-461.
Keywords :
calibration; electromagnetic compatibility; electromagnetic interference; MIL-STD-461/462; RS105 test system; calibration approaches; calibration method; electromagnetic interference standards; Calibration; Electromagnetic compatibility; Electromagnetic interference; Military standards; Transient analysis; MIL-STD-461; RS105; electromagnetic interference; system calibration; transient electromagnetic field;
Conference_Titel :
Antennas and Propagation (APCAP), 2014 3rd Asia-Pacific Conference on
Conference_Location :
Harbin
Print_ISBN :
978-1-4799-4355-5
DOI :
10.1109/APCAP.2014.6992794