DocumentCode
1776479
Title
Continuous condition monitoring of the electrical insulation of AC motors without disconnection
Author
Grebchenko, N.V. ; Smirnova, M.A. ; Kozhukhar, A.V.
Author_Institution
Fac. of Electr. Eng., Donetsk Nat. Tech. Univ., Donetsk, Ukraine
fYear
2014
fDate
18-20 June 2014
Firstpage
512
Lastpage
514
Abstract
A new method of monitoring the condition of the electrical insulation of the stator windings of AC motors and increasing the sensitivity of current protection against phase-to-ground faults are proposed. The method is based on the introduction of an additional magnetomotive force (m.m.f.) in a magnetic core of zero sequence current transformers. Frequency of this m.m.f. is different from the network power-frequency. The working algorithm of the device of control and protection of the feeders with the AC motors and the results of its tests in industrial environment are given.
Keywords
condition monitoring; current transformers; machine insulation; machine protection; magnetic cores; stators; AC motors; continuous condition monitoring; control device; current protection; electrical insulation; feeders protection; industrial environment; magnetic core; magnetomotive force; network power-frequency; phase-to-ground faults; stator windings; zero sequence current transformers; AC motors; Current transformers; Insulation; Magnetic cores; Monitoring; Sensitivity; Windings; AC motor; control of insulation; phase-to-ground fault; power cable; protection; sensitivity; zero sequence current transformer;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM), 2014 International Symposium on
Conference_Location
Ischia
Type
conf
DOI
10.1109/SPEEDAM.2014.6871941
Filename
6871941