DocumentCode :
1778843
Title :
The Application of LRL Technique for Calibrating the Automatic Network Analyzer
Author :
Cao Yun ; Chen Huaiyan
Author_Institution :
Dept. of Meas., Beijing Aerosp. Control Center, Beijing, China
fYear :
2014
fDate :
18-20 Sept. 2014
Firstpage :
265
Lastpage :
268
Abstract :
LRL technique for calibrating the automatic network analyzer is presented. LRL technique is a variation of TRL, it is especially useful for microwave, non-coaxial environments. This technique would enhance the accuracy extent of calibration. Detailed information about the choice of LRL calibration kits and LRL calibration steps are given. In addition, an measurement example using LRL calibration approves LRL technique is valid.
Keywords :
calibration; measurement errors; measurement uncertainty; network analysers; LRL calibration technique; automatic network analyzer; measurement accuracy; measurement errors; Accuracy; Calibration; Frequency measurement; Measurement uncertainty; Standards; Transmission line matrix methods; Transmission line measurements; LRL; air line; calibration; error model; measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement, Computer, Communication and Control (IMCCC), 2014 Fourth International Conference on
Conference_Location :
Harbin
Print_ISBN :
978-1-4799-6574-8
Type :
conf
DOI :
10.1109/IMCCC.2014.62
Filename :
6995032
Link To Document :
بازگشت