Title :
Influence of ion concentration in aqueous solution on sterilization of E. coli by high electric field pulse
Author :
Murakami, Yasutaka ; Muramoto, Yoshifumi ; Shimizu, N.
Author_Institution :
Dept. of Electr. & Electron. Eng., Meijo Univ., Nagoya, Japan
Abstract :
We have been investigating sterilization of liquid food by high electric field pulse. In this paper, high electric field pulse is applied to aqueous solution with Escherichia coli changing the components of the solution. As results, the survival rate of samples decreases with the ion concentration in aqueous solution. We consider that the performance of high electric field pulse sterilization depends on an amount of Cl- in aqueous solution, but the amount of Na+, K+, or Cs+ has no effect on the survival rate.
Keywords :
electric field effects; food processing industry; food products; food safety; microorganisms; sterilisation (microbiological); Cl-; Escherichia coli; aqueous solution; high electric field pulse sterilization; ion concentration; liquid food; survival rate; Atomic measurements; Electric fields; Electrodes; Ions; Liquids; Microorganisms; Stress; Escherichia coli; high electric field pulse; ion concentration; sterilization;
Conference_Titel :
Electrical Insulation and Dielectric Phenomena (CEIDP), 2014 IEEE Conference on
Conference_Location :
Des Moines, IA
DOI :
10.1109/CEIDP.2014.6995778