DocumentCode :
1780116
Title :
Research the length of the positive corona using the digital image processing technology
Author :
Ye Qizheng ; Xingwang Li ; Yu Hu ; Yi Sun
Author_Institution :
Sch. of Electr. & Electron. Eng., Huazhong Univ. of Sci. & Technol., Wuhan, China
fYear :
2014
fDate :
19-22 Oct. 2014
Firstpage :
98
Lastpage :
101
Abstract :
This paper presents an experimental study of dc air discharge in a point-line electrode system. The digital image processing technology presented in our previously paper is used to calculate the length of the positive corona. The calculated results of the mean gray level, the standard deviation of the gray levels and the coefficient of variation which is the ratio of the standard deviation to the mean gray level, show that the jump location of the coefficient of variation is the end point of the corona and can be used as an index of the length of corona. With an increase of the voltage, the length of corona increases and the positive corona mingles with the negative corona at last. Compared with the other methods, the method is not only effective but also simple in the quantitative analysis the length of the corona.
Keywords :
corona; discharges (electric); electrical engineering computing; electrodes; image processing; coefficient of variation; digital image processing technology; electrical discharge; mean gray level; point-line electrode system; positive corona; Corona; Image processing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena (CEIDP), 2014 IEEE Conference on
Conference_Location :
Des Moines, IA
Type :
conf
DOI :
10.1109/CEIDP.2014.6995835
Filename :
6995835
Link To Document :
بازگشت