Abstract :
This paper presents simultaneous measurements using three methods of partial discharge detection on 15kV high voltage cable sections with artificially created fault geometries, namely a semiconductor point and a large and small metal particle embedded on the insulation. These faults are simultaneously investigated using two 20MHz bandwidth HFCTs and an IEC60270 system. The peak value of one of the HFCT signals is measured to produce φ-q-n pattern plots and the other is used to generate an HFCT electromagnetic interference (EMI) frequency spectra. IEC60270 φ-q-n patterns are also simultaneously produced for comparison. Measurements are synchronised in time and trended allowing comparisons between the methods to be investigated for changes in characteristic behaviour. Correlations between primary statistical parameters of the φ-q-n patterns and identified signature HFCT EMI frequency band changes are highlighted in order to show the key distinctive characteristics for the faults considered. It is also shown that by understanding and correlating simultaneous HFCT EMI spectra and HFCT peak φ--q-n pattern measurements it may be possible to determine, with some confidence, the nature of the fault rather than relying on a direct contact IEC60270 measurement system.
Keywords :
cables (electric); current transformers; electrical faults; electromagnetic interference; high-frequency transformers; high-voltage techniques; partial discharge measurement; statistical analysis; HFCT electromagnetic interference frequency spectra; HFCT peak φ-q-n pattern measurements; HV cable fault geometry analysis; bandwidth 20 MHz; characteristic behaviour; correlated bandwidth HFCT signal measurement; direct contact IEC60270 measurement system; high frequency current transformer; high voltage cable sections; key distinctive characteristics; metal particle; partial discharge detection methods; peak value; primary statistical parameters; semiconductor point; signature HFCT EMI frequency band changes; time synchronisation; voltage 15 kV; Atmospheric measurements; Electromagnetic interference; Frequency measurement; Partial discharge measurement; Partial discharges; Particle measurements; Semiconductor device measurement; HFCT; IEC60270; Partial Discharge;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena (CEIDP), 2014 IEEE Conference on
Conference_Location :
Des Moines, IA
Type :
conf
DOI :
10.1109/CEIDP.2014.6995846
Filename :
6995846
Link To Document :
بازگشت