DocumentCode :
1785410
Title :
Transmission pricing using power flow tracing methodology with consideration N-1 security criterion
Author :
Rathore, Pawan ; Agnihotri, Ganga ; Khan, Bilal ; Gupta, Gaurav
Author_Institution :
Dept. of Electr. Eng., Maulana Azad Nat. Inst. of Technol., Bhopal, India
fYear :
2014
fDate :
28-30 May 2014
Firstpage :
1
Lastpage :
6
Abstract :
The transmission usage cost allocation is one of the major issues experienced by the Electric Supply Industries. A technique is proposed which is based on graph theory for the transmission usage cost allocation to generators. The proposed impact factor is used to allocate transmission usage cost to generator based on the contributions to maximum line flows under N-1 contingency condition. For allocating the cost, Line Outage Impact Factor (LOIF) and proposed Maximum Line Outage Impact Factor (MLOIF) is used. For transmission usage cost allocation modified MW-Mile method is used. IEEE 14 bus system is used to explain the feasibility of the proposed methodology.
Keywords :
graph theory; power system security; power transmission economics; pricing; IEEE 14 bus system; LOIF; MLOIF; N-1 contingency condition; N-1 security criterion; electric supply industries; graph theory; line outage impact factor; maximum line flows; maximum line outage impact factor; power flow tracing methodology; transmission pricing; transmission usage cost allocation; Electricity; Generators; Load flow; Power system reliability; Reliability; Resource management; Modified Kirchhoff matrix; power flow tracing; transmission cost allocation; transmission pricing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering and Systems (SCES), 2014 Students Conference on
Conference_Location :
Allahabad
Print_ISBN :
978-1-4799-4940-3
Type :
conf
DOI :
10.1109/SCES.2014.6880071
Filename :
6880071
Link To Document :