• DocumentCode
    1785627
  • Title

    The new detection of eccentricity faults in Switched Reluctance Motor

  • Author

    Nikooie, Melika ; Afjei, E. ; Siadatan, A.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., West Tehran Branch-Islamic Azad Univ., Tehran, Iran
  • fYear
    2014
  • fDate
    20-22 May 2014
  • Firstpage
    654
  • Lastpage
    658
  • Abstract
    This paper presents a new method for eccentricity fault diagnosis in switched reluctance motor (SRM). This method makes it possible to determine the eccentricity faulty phase. The proposed signature is based on the analysis of produced currents. It is theoretically shown that the occurrence of the fault level cause an increase in amplitude of the produced current, which can be employed to diagnose the fault. According to the obtained results by theoretical analysis, a pattern is introduced in order to detect fault location or faulty phase. A test bed in the laboratory is established to perform various measurements on the eccentric motor with different fault levels.
  • Keywords
    fault location; reliability; reluctance motors; SRM; eccentric motor; eccentricity fault diagnosis; eccentricity faulty phase detection; fault location detection; switched reluctance motor; Computers; Current measurement; Educational institutions; Rotors; Stators; Switched reluctance motors; eccentricity; fault diagnosis; produced current; switched reluctance motor;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Engineering (ICEE), 2014 22nd Iranian Conference on
  • Conference_Location
    Tehran
  • Type

    conf

  • DOI
    10.1109/IranianCEE.2014.6999621
  • Filename
    6999621