DocumentCode
1785627
Title
The new detection of eccentricity faults in Switched Reluctance Motor
Author
Nikooie, Melika ; Afjei, E. ; Siadatan, A.
Author_Institution
Dept. of Electr. & Comput. Eng., West Tehran Branch-Islamic Azad Univ., Tehran, Iran
fYear
2014
fDate
20-22 May 2014
Firstpage
654
Lastpage
658
Abstract
This paper presents a new method for eccentricity fault diagnosis in switched reluctance motor (SRM). This method makes it possible to determine the eccentricity faulty phase. The proposed signature is based on the analysis of produced currents. It is theoretically shown that the occurrence of the fault level cause an increase in amplitude of the produced current, which can be employed to diagnose the fault. According to the obtained results by theoretical analysis, a pattern is introduced in order to detect fault location or faulty phase. A test bed in the laboratory is established to perform various measurements on the eccentric motor with different fault levels.
Keywords
fault location; reliability; reluctance motors; SRM; eccentric motor; eccentricity fault diagnosis; eccentricity faulty phase detection; fault location detection; switched reluctance motor; Computers; Current measurement; Educational institutions; Rotors; Stators; Switched reluctance motors; eccentricity; fault diagnosis; produced current; switched reluctance motor;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Engineering (ICEE), 2014 22nd Iranian Conference on
Conference_Location
Tehran
Type
conf
DOI
10.1109/IranianCEE.2014.6999621
Filename
6999621
Link To Document