DocumentCode :
1788053
Title :
FPGA based preliminary CAD for kidney on IoT enabled portable ultrasound imaging system
Author :
Krishna, K. Divya ; Akkala, Vivek ; Bharath, R. ; Rajalakshmi, P. ; Mohammed, Abdul Mateen
Author_Institution :
Dept. of Electr. Eng., Asian Inst. of Gastroenterology, Hyderabad, India
fYear :
2014
fDate :
15-18 Oct. 2014
Firstpage :
257
Lastpage :
261
Abstract :
Ultrasound imaging has been widely used for preliminary diagnosis as it is non-invasive and has good scope for the doctors to analyze many diseases. Lack of trained sonographers make ultrasound imaging diagnosis time consuming to detect any abnormality. Sometimes the problem cannot exactly be identified which may lead to error in diagnosis. Hence in this paper we present computer aided automatic detection of abnormality in kidney on the ultrasound system itself, to decrease the time for reports and not to depend on the sonographer. We classified the kidney as normal and abnormal case. Segment the kidney region and extract Intensity histogram features and Haralick features from Gray Level Cooccurnace Matrix (GLCM). These features are calculated for a set of large data containing both normal and abnormal cases. Abnormal case includes kidney stone, cyst and bacterial infection. Standard deviation for each parameter is observed, considered only those features with less deviation and implemented on FPGA Kintex board. If the range of mean value is 1.08 to 1.336, skewness is 2.882 to 7.708, Kurtosis is 1.06 to 71.152, Cluster Shade is 72 to 243, Homogeneity is 0.993 to 0.998, the observed kidney image is normal otherwise abnormal.
Keywords :
CAD; biomedical ultrasonics; diseases; feature extraction; field programmable gate arrays; image classification; image segmentation; kidney; medical image processing; Cluster Shade; FPGA Kintex board; GLCM; Gray Level Cooccurnace Matrix; Haralick features; Homogeneity; IoT; Kurtosis; abnormal cases; abnormality; bacterial infection; computer aided automatic detection; cyst; disease; intensity histogram feature extraction; kidney classification; kidney image; kidney region segmentation; kidney stone; portable ultrasound imaging system; preliminary CAD; preliminary diagnosis; skewness; standard deviation; ultrasound imaging diagnosis; Design automation; Feature extraction; Field programmable gate arrays; Imaging; Kidney; Noise; Ultrasonic imaging; FPGA; Haralick features; Intensity histogram features; cloud; speckle;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
e-Health Networking, Applications and Services (Healthcom), 2014 IEEE 16th International Conference on
Conference_Location :
Natal
Type :
conf
DOI :
10.1109/HealthCom.2014.7001851
Filename :
7001851
Link To Document :
بازگشت