DocumentCode
1790762
Title
Radar cross section measurements in an anechoic chamber: Description of an experimental system and post processing
Author
Comblet, F.
Author_Institution
Lab.-STICC, ENSTA Bretagne, Brest, France
fYear
2014
fDate
16-19 Nov. 2014
Firstpage
1
Lastpage
4
Abstract
This paper deals with the RCS (Radar Cross Section) acquisition procedure in the anechoic chamber of ENSTA Bretagne. This device will be used in the comparison of RCS measurements organized by a French working group (GTi) [1]. One objective of this group is to determine uncertainties in an anechoic chamber from RCS measurements of different targets. In this paper, we present our experimental system and processing performed on the data to obtain the RCS of the object under test. The measurement results are given for canonical and complex targets. The measurements are then compared with some results of simulations computed with FEKO.
Keywords
anechoic chambers (electromagnetic); radar cross-sections; ENSTA Bretagne; FEKO; French working group; GTi; RCS acquisition procedure; anechoic chamber; canonical target; complex target; object under test; radar cross section measurement; Anechoic chambers; Antenna measurements; Antennas; Calibration; Noise; Noise measurement; Radar cross-sections;