• DocumentCode
    1792000
  • Title

    Total Dose Radiation Effects on COTS Array CCDs at Low Dose Rate

  • Author

    Wang Zujun ; Xiao Zhigang ; He Baoping ; Huang Shaoyan ; Tang Benqi ; Liu Minbo

  • Author_Institution
    State Key Lab. of Intense Pulsed Radiat. Simulation & Effect, Northwest Inst. of Nucl. Technol., Xi´an, China
  • fYear
    2014
  • fDate
    14-18 July 2014
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    The experiments of total dose effects on COTS array charge-coupled devices (CCDs) at the low dose rates of 0.01 and 0.03 rad(Si)/s are presented. The CCDs are divided into two groups,with one group biased and the other unbiased during 60-Co γ irradiation. The saturation output signal voltage, dark signal slope, and fixed pattern noise versus the total doses are presented. It is shown that the biased CCDs are degraded more severely than the unbiased CCDs, especially at a high total dose. The resolution of the CCD camera image is degraded remarkably after irradiation.
  • Keywords
    CCD image sensors; image resolution; radiation hardening (electronics); sensor arrays; CCD camera; COTS array; charge-coupled device; dark signal slope; fixed pattern noise; image resolution; saturation output signal voltage; total dose radiation effect; Arrays; Charge coupled devices; Image resolution; Noise; Radiation effects; Signal resolution; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Radiation Effects Data Workshop (REDW), 2014 IEEE
  • Conference_Location
    Paris
  • Print_ISBN
    978-1-4799-5883-2
  • Type

    conf

  • DOI
    10.1109/REDW.2014.7004605
  • Filename
    7004605