Title :
Total Dose Radiation Effects on COTS Array CCDs at Low Dose Rate
Author :
Wang Zujun ; Xiao Zhigang ; He Baoping ; Huang Shaoyan ; Tang Benqi ; Liu Minbo
Author_Institution :
State Key Lab. of Intense Pulsed Radiat. Simulation & Effect, Northwest Inst. of Nucl. Technol., Xi´an, China
Abstract :
The experiments of total dose effects on COTS array charge-coupled devices (CCDs) at the low dose rates of 0.01 and 0.03 rad(Si)/s are presented. The CCDs are divided into two groups,with one group biased and the other unbiased during 60-Co γ irradiation. The saturation output signal voltage, dark signal slope, and fixed pattern noise versus the total doses are presented. It is shown that the biased CCDs are degraded more severely than the unbiased CCDs, especially at a high total dose. The resolution of the CCD camera image is degraded remarkably after irradiation.
Keywords :
CCD image sensors; image resolution; radiation hardening (electronics); sensor arrays; CCD camera; COTS array; charge-coupled device; dark signal slope; fixed pattern noise; image resolution; saturation output signal voltage; total dose radiation effect; Arrays; Charge coupled devices; Image resolution; Noise; Radiation effects; Signal resolution; Voltage measurement;
Conference_Titel :
Radiation Effects Data Workshop (REDW), 2014 IEEE
Conference_Location :
Paris
Print_ISBN :
978-1-4799-5883-2
DOI :
10.1109/REDW.2014.7004605