Abstract
Biosensors based on the spectral correlation interferometry (SCI) with assistance of magnetic nanoparticles (MP) have been developed for medical diagnostics. The SCI has been adapted for studies of affinity constants of MP covered by antibodies and for detection of protein molecules in human serum. The 50-nm MP employed as labels yield 100-fold amplification of the SCI signals to meet the requirements for myocardial infarction diagnostics.
Keywords
biomedical equipment; biosensors; interferometry; magnetic particles; molecular biophysics; nanomagnetics; nanomedicine; nanoparticles; patient diagnosis; proteins; MP affinity constants; SCI signal amplification; antibodies; biomedical diagnosis; biomedical research; biosensors; human serum; magnetic nanoparticles; myocardial infarction diagnosis; protein molecule detection; spectral correlation interferometry; Biosensors; Glass; Myocardium; affinity constants; antibody; autoantibodies; biosensors; cardiac troponin I; interferometry; magnetic nanoparticles;