• DocumentCode
    1794927
  • Title

    Hardware implementation of quad microelectromechanical sensor structure for inertial systems

  • Author

    Iontchev, Emil ; Kenov, Radostin ; Miletiev, Rossen ; Simeonov, Ivan ; Isaev, Yavor

  • Author_Institution
    Higher Sch. of Transp. “T. Kableshkov”, Sofia, Bulgaria
  • fYear
    2014
  • fDate
    7-11 May 2014
  • Firstpage
    417
  • Lastpage
    420
  • Abstract
    The paper discusses the hardware implementation of the quad sensor structure and the possibility to improve the noise characteristics of the structure when simultaneously sampling is accomplished. The histograms of the linear and angular accelerations are given to proof the theory of the structure, published in our previous paper. This structure may be manufactured as a single MEMS inertial sensor with better noise parameters.
  • Keywords
    acceleration measurement; angular measurement; microsensors; angular acceleration histogram; hardware implementation; linear acceleration histogram; quadmicroelectromechanical sensor structure; single MEMS inertial sensor; Acceleration; Generators; Microcontrollers; Micromechanical devices; Noise; Synchronization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronics Technology (ISSE), Proceedings of the 2014 37th International Spring Seminar on
  • Conference_Location
    Dresden
  • Type

    conf

  • DOI
    10.1109/ISSE.2014.6887636
  • Filename
    6887636