Title :
Removal of EOG artifacts: Comparison of ICA algorithm from recording EEG
Author :
Kusumandari, Dwi Esti ; Fakhrurroja, Hanif ; Turnip, Arjon ; Hutagalung, Sutrisno Salomo ; Kumbara, Bagus ; Simarmata, Janner
Author_Institution :
Tech. Implementation Unit for Instrum. Dev., Indonesian Inst. of Sci., Bandung, Indonesia
Abstract :
Electroencephalogram (EEG) is the activity of bioelectrical signals that recorded from electrodes on the scalp. In EEG recording, the signal obtained is not entirely derived from the brain, but may be contaminated by other signals such as Electrooculogram (EOG), Electrocardiogram (ECG) and Electromiogram (EMG). EEG signals that recorded, especially by electrodes located near the eyes, will be affected by EOG. So that necessary action is needed to eliminate or reduce these EEG signals artifacts. This paper proposed a method using ICA for EOG artifact removal and compared which ICA algorithm (JADE and SOBI) is more effective and has better results in the removal of EOG artifacts in EEG recording.
Keywords :
electro-oculography; electrocardiography; electroencephalography; independent component analysis; medical signal processing; signal denoising; ECG; EEG signal artifact elimination; EEG signal artifact reduction; EEG signal recording; EMG; EOG artifact removal; ICA algorithm; JADE; SOBI; bioelectrical signal recording; electrocardiogram; electrodes; electroencephalogram; electromiogram; electrooculogram; independent component analysis; signal contamination; Algorithm design and analysis; Covariance matrices; Electrodes; Electroencephalography; Electrooculography; Principal component analysis; Signal processing algorithms; EEG Artifacts; EOG; ICA; JADE; SOBI;
Conference_Titel :
Technology, Informatics, Management, Engineering, and Environment (TIME-E), 2014 2nd International Conference on
Conference_Location :
Bandung
Print_ISBN :
978-1-4799-4806-2
DOI :
10.1109/TIME-E.2014.7011642