DocumentCode :
1800999
Title :
The design of intelligent preamplifier for turbine flow transducers
Author :
Zhu Hui ; Shen Yuming
Author_Institution :
Univ. of Shanghai for Since & Technol., Shanghai, China
fYear :
2013
fDate :
26-28 July 2013
Firstpage :
8369
Lastpage :
8372
Abstract :
The design of intelligent preamplifier for turbine flow transducers based on MCU-51 has been put forward, include implementations of theoretical model of nonlinear compensation, circuit and software. Experiments also have been carried out. The transducer meter factor can be modified on-line by using piecewise nonlinear compensation method. The intelligent preamplifier output corrected pulse signal which is propotional to the average meter factor. The experimental results show that with intelligent preamplifier, the accuracy of flow measurement is improved to ±0.5% or less and the flow range can be enlarged to 10.1.
Keywords :
design engineering; flow measurement; preamplifiers; transducers; turbines; MCU-51; design; flow measurement; intelligent preamplifier; nonlinear compensation; piecewise nonlinear compensation method; transducer meter factor; turbine flow transducers; Abstracts; Educational institutions; Electronic mail; Integrated circuit modeling; Preamplifiers; Transducers; Turbines; Compensation; Nonlinear Error; Preamplifier; Turbine Flow Meter;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Control Conference (CCC), 2013 32nd Chinese
Conference_Location :
Xi´an
Type :
conf
Filename :
6640919