• DocumentCode
    1808319
  • Title

    Development of a simple in situ instrumentation for detection of breath alcohol and gas leak

  • Author

    Wagiran, R. ; Chong, Alan G E ; Ahmad, I. ; Salleh, A.B.

  • Author_Institution
    Inst. of Biosci., Univ. Putra Malaysia, Selangor, Malaysia
  • fYear
    2002
  • fDate
    19-21 Dec. 2002
  • Firstpage
    470
  • Lastpage
    474
  • Abstract
    The objective of this project is to develop a multiple-detector-system which consists of two systems that are toxic gas detector system and breath alcohol detector. A microcontroller of PIC 16F84, a gas sensor (TGS822), an analog to digital (A/D) TLC 549, and LCD alphanumeric display were used. Both systems are mounted on the same PCB board, a DPDT switch is used for the purpose for switching systems either switch from toxic gas detector system to breath alcohol detector system and vice versa. The systems were tested using butane gas from cigarette´s lighter as well as from human´s breath and it worked satisfactory.
  • Keywords
    analogue-digital conversion; gas sensors; liquid crystal displays; microcontrollers; LCD alphanumeric display; PIC 16F84; analog-to-digital converter; breath alcohol detector; gas sensor; microcontroller; multiple-detector-system; switching systems; toxic gas detector; Circuits; Conductivity; Gas detectors; Instruments; Leak detection; Liquid crystal displays; Microcontrollers; Sensor phenomena and characterization; Solvents; Switches;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Semiconductor Electronics, 2002. Proceedings. ICSE 2002. IEEE International Conference on
  • Print_ISBN
    0-7803-7578-5
  • Type

    conf

  • DOI
    10.1109/SMELEC.2002.1217868
  • Filename
    1217868