• DocumentCode
    1814715
  • Title

    Effect of venous compliance on left ventricular stroke work at different heart rates

  • Author

    Wang, Jia-Jung ; Drzewiecki, Gary ; Li, John K-J

  • Author_Institution
    Dept. of Biomed. Eng., Rutgers Univ., Piscataway, NJ, USA
  • fYear
    1996
  • fDate
    14-15 Mar 1996
  • Firstpage
    64
  • Lastpage
    65
  • Abstract
    Effect of the venous compliance amplitude on left ventricular work, especially during systemic or pulmonary chronic edema, was studied in this paper via a computer model. The model contains three parts: the left ventricle (LV), preload equivalent and afterload equivalent. Based on continuity, it was assumed that the aortic blood flow must, on average, equal the venous return. The modeling results show that for constant contractile function, higher venous compliance shifts the maximum of LV stroke work per beat to a higher heart rate. It was concluded that venous compliance alters the heart rate at which the power output of the left ventricle is a maximum
  • Keywords
    biology computing; biomechanics; cardiology; digital simulation; elasticity; haemodynamics; physiological models; afterload equivalent; aortic blood flow; computer model; heart rate; left ventricle power output; left ventricular stroke work; preload equivalent; pulmonary chronic edema; systemic edema; venous compliance effect; venous return; Analog circuits; Biomedical computing; Biomedical engineering; Blood flow; Cardiology; Cardiovascular system; Filling; Heart rate; Laboratories; Valves;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Bioengineering Conference, 1996., Proceedings of the 1996 IEEE Twenty-Second Annual Northeast
  • Conference_Location
    New Brunswick, NJ
  • Print_ISBN
    0-7803-3204-0
  • Type

    conf

  • DOI
    10.1109/NEBC.1996.503219
  • Filename