DocumentCode :
1816501
Title :
Design and test of power supply system for ATLAS muon spectrometer
Author :
Beretta, Matteo M. ; Lanza, Agostino ; Vandelli, Wainer R. ; Mikenberg, George ; Richter, Robert
Author_Institution :
Laboratori Nazionali di Frascati, Italy
Volume :
2
fYear :
2003
fDate :
19-25 Oct. 2003
Firstpage :
1133
Abstract :
In this paper, the problem of the Low Voltage (LV) and High Voltage (HV) power supply distribution of the MDT (Monitored Drift Tubes) detector is addressed. Due to the high number of channels (1168 for low voltage and twice for high voltage) involved and to the dimension of the apparatus, these power supply systems are very complicated. Both system are made of three different parts: a power generator, a system controller and an active distributor. The first two parts will be localized in the cavern close to the experimental area, so they are subjected to standard environmental conditions. The third part (the active distributor) will be placed in the experimental area on the platforms just outside the detector, where the environmental conditions are more severe, due to the presence of magnetic field (about 800 Gauss) and radiations. In the following we present the design specifications and tests for the power supply systems.
Keywords :
muon detection; particle spectrometers; power supplies to apparatus; ATLAS muon spectrometer; Monitored Drift Tubes detector; power supply system; Control systems; Detectors; Low voltage; Mesons; Monitoring; Power generation; Power supplies; Spectroscopy; System testing; Umbilical cable;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2003 IEEE
ISSN :
1082-3654
Print_ISBN :
0-7803-8257-9
Type :
conf
DOI :
10.1109/NSSMIC.2003.1351891
Filename :
1351891
Link To Document :
بازگشت