This paper describes the development work leading to the design and testing work of a new corona shield for AREVA´s 800 kV Ultra High Voltage Direct Current (UHVDC) thyristor valve. The design of the corona shields required an extensive electrostatic field investigation using numerical analysis, particularly the Boundary Element Method (BEM), an enhancement of the well known Finite Element analysis to calculate electrical stress. Some results from the laboratory tests are presented in the paper together with an assessment of the initial BEM analysis. The paper concludes by considering how the electrical clearances identified in the tests influence the design, and hence achieve an economically viable corona shield design for ±800 kV UHVDC convertor stations.
Keywords
HVDC power convertors; boundary-elements methods; thyristors; HVDC; boundary element method; converter stations; corona shields; electrical stress; electrostatic field; thyristor valves; ultra high voltage direct current; Boundary element methods; Corona; Electrostatics; Finite element methods; HVDC transmission; Numerical analysis; Testing; Thyristors; Valves; Voltage; 800 kV; BEM; Clearance; Corona shield; Electric Stress; HVDC; Prototype; SI Test; Thyristor Valve; UHVDC;
fLanguage
English
Publisher
ieee
Conference_Titel
Universities Power Engineering Conference (UPEC), 2009 Proceedings of the 44th International
Conference_Location
Glasgow
Print_ISBN
978-1-4244-6823-2
Type
conf
Filename
5429381
Link To Document