DocumentCode
1819381
Title
Study on the characteristic parameters used to assess the insulation condition of stator winding
Author
Bo, Yue ; Zhelei, Zhu ; Xiaolin, Chen ; Xie, Hengkun
Author_Institution
State Key Lab. of Electr. Insulation for Power Equipment, Xi´´an Jiaotong Univ., China
Volume
1
fYear
2003
fDate
1-5 June 2003
Firstpage
278
Abstract
In this paper, a multistress aging system was established and the accelerated aging experiment based on the stator bar of 780 kW/6 kV large motor had been conducted in the laboratory. The experiment results show that tanδE (the dielectric dissipation factor at the line-ground voltage), Pi2 (the second AC current rapid increase voltage) and Nq (the increase rate of maximum PD quantity) can be used as characteristic parameters to evaluate the aging condition of stator winding insulation.
Keywords
AC machines; ageing; electric breakdown; electric motors; partial discharges; stators; AC current; dielectric dissipation factor; insulation condition; multistress aging system; partial discharge; stator bar; stator winding; stator winding insulation; Accelerated aging; Dielectric measurements; Dielectrics and electrical insulation; Laboratories; Residual stresses; Stator windings; Testing; Thermal stresses; Vibrations; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Properties and Applications of Dielectric Materials, 2003. Proceedings of the 7th International Conference on
ISSN
1081-7735
Print_ISBN
0-7803-7725-7
Type
conf
DOI
10.1109/ICPADM.2003.1218406